Solar Pump Check Valve Leakage: Reading Pressure After Shutdown
When pressure falls after a solar well pump stops, water may be returning toward the well, leaving through the delivery system, or simply redistributing between sections. A single gauge cannot distinguish those cases. The useful question is where pressure changes first, what else was open at that moment, and whether the same sequence repeats with comparable starting conditions.

This guide is for operators and service teams investigating a pressurized delivery line on a single-pump installation. It is not a valve sizing guide or a field procedure for opening pressurized equipment. If the system bangs, shakes, leaks externally, or exceeds an equipment limit, stop testing and have the installer investigate. For valve placement and surge considerations, see our solar pump check valve and water hammer guide.
Start by drawing the pressure zones
Sketch the path from the pump outlet to the delivery point. Mark every known non-return valve, gauge, branch, tank, relief outlet and discharge point. A well may have a valve downhole and another at the surface. If the surface valve holds, a gauge on its downstream side may remain steady even while the pipe below loses water. Label readings by location, not just as inlet and outlet. Two gauges that are on the same side of both valves cannot tell you what happened between the valves.
Record where the line is intended to hold pressure. A system discharging into a vented tank may normally lose pressure after shutdown or may drain back by design. A pressure vessel, by contrast, may continue supplying a small demand after the motor stops. An expected refill or drain sequence should not be treated as a fault. Ask the installer for the operating description before interpreting the trace.
Define the moment the pump stopped
Start the record at the controller event that indicates the motor actually stopped, not when the operator first saw the display change or when the logger uploaded the file. A solar controller can slow a pump before it stops. In a weak-sun event, the final running pressure may be quite different from the final pressure after a normal tank-full stop. Comparing those traces as though the starting conditions were identical can create a false diagnosis.
Mark the stop reason, initial pressure and any known changes in outlet state. At approved observation points, capture the immediate change separately from the later slope. A digital logger that only records occasional snapshots may miss short pressure changes; an analog gauge may be hard to read while the needle moves. Report the resolution you actually have. A single sampled drop is not proof of the size, duration or direction of a pressure surge.
Pressure-decay field worksheet
Layout: sketch and name each existing measurement location and indicate which valves separate them.
Start state: log stop reason, pressure just before stopping, tank state, outlet demand and the status of any automatic cycle.
Pressure series: record time since confirmed stop, gauge location, pressure and units. Mark when the instrument first settled; preserve the raw readings.
Independent observations: note meter direction only if the meter supports it, tank level changes, visible discharge and unexpected controller restarts.
Comparison: state whether initial pressure, branch status, gauge placement and stop reason were comparable. Record any difference that could explain the result.
Service decision: identify the next unverified branch or pipe section. Do not list a failed part until the evidence supports it.
Use the same units and record gauge elevations when comparing locations. A gauge closer to the ground can read differently from one higher up even when both are observing the same connected water column. A discrepancy smaller than instrument resolution does not separate two fault hypotheses.
Read the pattern before naming a faulty valve
If both gauges are downstream of the check valve and lose pressure together, look for documented demand, a bypass or a discharge path on that side. An irrigation valve that is supposed to close may still be passing water, and a tank can supply it after the pump stops. A pressure drop with no water visible at the main outlet does not exclude a buried branch or a separate drain. Record whether the metered delivery volume increased while the pump was off.
If the accessible reading on the well side falls while the delivery side holds, look at the well-side section and the valves defining it. The result is consistent with loss on that side, but a pipe defect, drain provision or gauge issue may produce a similar record. Where the system design supports safe sectional testing, ask the installer to use the approved isolation points and to document what each test includes. Do not close valves against a running pump or improvise a test by creating a trapped, pressurized section.
A gauge that jumps, freezes, or shows a change that is absent from a second suitable instrument warrants an instrument check. Verify the unit setting, timestamp, range and where the pressure tap connects. A meter with no reverse-flow recording cannot prove that backflow did not occur. Likewise, pressure decline by itself is not a leak-rate measurement: the water volume represented by a pressure change depends on the tank, piping and trapped air.
Example: two shutdowns with different evidence
Suppose a qualified operator records two normal stops from approximately the same delivery pressure. In the first, an irrigation timer runs a brief zone cycle immediately after shutdown; the downstream meter records delivery and pressure drops. In the second, no zone cycle is recorded, but the accessible well-side gauge drops while the delivery-side reading stays steady. These are hypothetical observations, not acceptance thresholds. The first points to downstream use; the second narrows the investigation to the section on the well side of the separating valve. Neither result identifies a replacement part by itself.
Do not run extra starts to reproduce a suspected surge. Grundfos explains how a leaking lower non-return valve and a tight upper valve can leave a partial vacuum and create a surge on restart. Its advice is to stop the system and bring in the installer when surges occur. For submersible installation and service documentation, refer to the Franklin Electric AIM manuals and installation record forms. Use the instructions for the actual equipment and site; these references do not establish RUTANPUMP model-specific test limits.
Frequently asked questions
Does steady pressure at the surface rule out a leaking downhole check valve?
No. If another valve separates the gauge from the downhole section, it can hold pressure on the side the gauge sees while pressure falls elsewhere. Establish which section the gauge measures before drawing a conclusion.
Can I compare a low-sun stop with a full-tank stop?
You can compare the sequence of events, but do not treat the traces as equivalent. Initial pump speed, pressure and valve states may differ. Record both stop reasons and avoid interpreting a different initial pressure as evidence that a leak got worse.
What should I send a service team before ordering a valve?
Send the pipe sketch, valve locations, pump and controller model, normal shutdown reason, readings with time and location, and whether outlets were active. Include photographs of accessible labels and notes about unusual noise. Ask which section and part identification still need confirmation before ordering.
Request help interpreting a shutdown trace
Contact RUTANPUMP / Wenling Jingzhan Mechanical & Electrical Co., Ltd. through the service inquiry page. Include the worksheet and say whether your priority is identifying the leaking section, evaluating an instrument discrepancy or documenting a potential surge. Email sales@rutanpump.com; WhatsApp/WeChat +86 18267835331. Telephone: +86 (0576) 86322398. Browse the solar water pump knowledge base for related design and service guides.